Equipment Design

map can join the customer's engineering design project, using AutoCAD and other engineering drawing software, as well as SW6, Compress and PV Elite and other equipment calculation software, to assist customers to complete the drawing and design of static equipment such as containers, heat exchangers, towers, etc. At the same time, the Chinese map can also cooperate with customers to produce inquiry drawings, mechanical design data sheets and other procurement technical documents.

regular equipment-beltjacketed mixing vessel2015-Nanjing-PV Elite

: the lower end of the cylinder is jacketed, the inner diameter of the equipment is 5300mm, the total height is about 13.5m, the medium characteristic is lethal, the volume is 195 cubic meters, and the main material is C.S. 10276 composite plate. The design standard is ASME Ⅷ-1, and the calculation software is PV Elite.

regular Equipment-Special Material Heat Exchanger Design Case 2015-Shanghai-PV Elite

: heat exchange area 610m2, the main material of the tube pass is C.S. 10276 composite plate, and the tube plate is C.S. Ti Zr composite of three layers of different materials. The design standard is ASME Ⅷ-1, and the calculation software is PV Elite.

regular Equipment-Double Tubeseplate Heat Exchanger Design Case 2016-Shanghai-SW6

the high toxicity of the medium in the tube side of the equipment, the double tube plate structure is used, and the structure is checked and calculated with the help of the latest version of SW6 software.

regular Equipment-Tower Design Case 2015-Shanghai-PV Elite

: the total height of the tower is about 46m. The assembly weight is 130t, the design standard is ASME Ⅷ-1, and the calculation software is PV Elite.

Pressure Vessel-Tower Construction Reinforcementstructural strength and stability analysisCase 2014-Nanjing-Ansys

a maintenance project: due to the serious corrosion of the middle barrel of the equipment, the barrel needs to be replaced. during the construction process, a reinforced structure is required to temporarily support the equipment, and finite element analysis is used to help customers check the strength and stability of the reinforced structure.

regular Equipment-Water TreatmentindustryequipmentCase2016-SHANGHAI-SW6 & PV Elite

provides technical support and equipment design services for the water treatment industry, according to HG/T 20696-1999,JB/T 2932-1999,GB 150-2011,ASME. VIII.Div. 1. Design FRP tanks, plastic tanks, pressure vessels, ladder platforms, steel structure platforms, pressure vessels, container containers and other equipment according to other standards, and provide technical support for equipment suppliers such as filters.

Fouling Heat Exchanger-Nanjing-Aspen EDR

the heat exchanger before the transformation of serious fouling, an average of 1 to 2 months to stop maintenance, seriously affecting the normal production and operation, through the analysis of the causes of the heat exchanger fouling, put forward the transformation scheme, the structure of the heat exchanger was modified, the transformation of the fouling phenomenon has been significantly improved. The picture shows the structure before and after the transformation: (screenshot)

Heat Exchange Equipment-Nanjing-Aspen EDR

A device heat exchanger due to heat exchange tube vibration caused by medium leakage, resulting in corrosion under the scale, so that the equipment leakage failure. The heat exchange tube is worn at the junction of the heat exchange tube and the baffle plate, and a large area of ulcer-like corrosion pits occur on the outer surface of the tube bundle. Through the analysis of the causes of failure, the transformation scheme is proposed: eliminate vibration, completely solve the problem of heat exchange tube leakage, transform the heat exchange tube bundle, and at the same time, in order to prevent the concentration of harmful ions in the process water, a sewage outlet is added to strengthen the discharge of concentrated sewage in the lower part of the shell process. The following figure shows the structure before and after the transformation: (screenshot)

service solution